forked from Qortal/Brooklyn
92 lines
2.9 KiB
Plaintext
92 lines
2.9 KiB
Plaintext
charger-manager bindings
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Required properties :
|
|
- compatible : "charger-manager"
|
|
- <>-supply : for regulator consumer, named according to cm-regulator-name
|
|
- cm-chargers : name of chargers
|
|
- cm-fuel-gauge : name of battery fuel gauge
|
|
- subnode <regulator> :
|
|
- cm-regulator-name : name of charger regulator
|
|
- subnode <cable> :
|
|
- cm-cable-name : name of charger cable - one of USB, USB-HOST,
|
|
SDP, DCP, CDP, ACA, FAST-CHARGER, SLOW-CHARGER, WPT,
|
|
PD, DOCK, JIG, or MECHANICAL
|
|
- cm-cable-extcon : name of extcon dev
|
|
(optional) - cm-cable-min : minimum current of cable
|
|
(optional) - cm-cable-max : maximum current of cable
|
|
|
|
Optional properties :
|
|
- cm-name : charger manager's name (default : "battery")
|
|
- cm-poll-mode : polling mode - 0 for disabled, 1 for always, 2 for when
|
|
external power is connected, or 3 for when charging. If not present,
|
|
then polling is disabled
|
|
- cm-poll-interval : polling interval (in ms)
|
|
- cm-battery-stat : battery status - 0 for battery always present, 1 for no
|
|
battery, 2 to check presence via fuel gauge, or 3 to check presence
|
|
via charger
|
|
- cm-fullbatt-vchkdrop-volt : voltage drop (in uV) before restarting charging
|
|
- cm-fullbatt-voltage : voltage (in uV) of full battery
|
|
- cm-fullbatt-soc : state of charge to consider as full battery
|
|
- cm-fullbatt-capacity : capcity (in uAh) to consider as full battery
|
|
- cm-thermal-zone : name of external thermometer's thermal zone
|
|
- cm-battery-* : threshold battery temperature for charging
|
|
-cold : critical cold temperature of battery for charging
|
|
-cold-in-minus : flag that cold temperature is in minus degrees
|
|
-hot : critical hot temperature of battery for charging
|
|
-temp-diff : temperature difference to allow recharging
|
|
- cm-dis/charging-max = limits of charging duration
|
|
|
|
Deprecated properties:
|
|
- cm-num-chargers
|
|
- cm-fullbatt-vchkdrop-ms
|
|
|
|
Example :
|
|
charger-manager@0 {
|
|
compatible = "charger-manager";
|
|
chg-reg-supply = <&charger_regulator>;
|
|
|
|
cm-name = "battery";
|
|
/* Always polling ON : 30s */
|
|
cm-poll-mode = <1>;
|
|
cm-poll-interval = <30000>;
|
|
|
|
cm-fullbatt-vchkdrop-volt = <150000>;
|
|
cm-fullbatt-soc = <100>;
|
|
|
|
cm-battery-stat = <3>;
|
|
|
|
cm-chargers = "charger0", "charger1", "charger2";
|
|
|
|
cm-fuel-gauge = "fuelgauge0";
|
|
|
|
cm-thermal-zone = "thermal_zone.1"
|
|
/* in deci centigrade */
|
|
cm-battery-cold = <50>;
|
|
cm-battery-cold-in-minus;
|
|
cm-battery-hot = <800>;
|
|
cm-battery-temp-diff = <100>;
|
|
|
|
/* Allow charging for 5hr */
|
|
cm-charging-max = <18000000>;
|
|
/* Allow discharging for 2hr */
|
|
cm-discharging-max = <7200000>;
|
|
|
|
regulator@0 {
|
|
cm-regulator-name = "chg-reg";
|
|
cable@0 {
|
|
cm-cable-name = "USB";
|
|
cm-cable-extcon = "extcon-dev.0";
|
|
cm-cable-min = <475000>;
|
|
cm-cable-max = <500000>;
|
|
};
|
|
cable@1 {
|
|
cm-cable-name = "SDP";
|
|
cm-cable-extcon = "extcon-dev.0";
|
|
cm-cable-min = <650000>;
|
|
cm-cable-max = <675000>;
|
|
};
|
|
};
|
|
|
|
};
|